TRNSYS 16 Fix list
This document lists the fixes made to various pieces of the TRNSYS package in response to noted operational problems or inadequacies. They are organized by TRNSYS release and by category (package, Source Code, Studio, Building, TRNEdit/TRNExe)
Fixes in TRNSYS 16.01.0003 (2007-03-28)
Package
0136 Doc: Corrected documentation for Type 27, as it mentioned plotting capabilities which are not available now.
0137 Example: New example shows how to use the detailed single zone building Type9.
0138 Example: Added a new example that shows the differences between controllers Type8 (thermostat) and Type2 (differential controller).
0139 Doc: Updated volume 8 Programmer's guide, reference to section 8.4.5 Solving differential equations.
0140 Doc: Added explanation of energy balance for Type31.
0141 Doc: Corrected the third level of titles in Volume 5.
0142 Doc: Fixed bookmarks in documentation for volumes 4 and 5.
0143 Example: calling matlab was updated in order to allow several instances of Type155
0144 Example: calling matlab had an old temporary file. It was deleted
0147 Example: electrolyzer controller was modified to work with IVF
0148 Doc: TRNEdit- explanation of EQSOLVER used the wrong range of values
0149 Example: Added a new example that shows how to create a HVAC system coupled to the building
0150 Example: Added example that shows how to solve for a component input, knowing the value of the output
Source Code (Kernel and Standard library of components)
1237 Example 'Electrollyzer Controller' works with IVF
1278 Fixed bug in Type65. If more than 5 units are present, the first 5 produce an online plotter and the others print to a file.
1281 Type109 - fixed bug with tracking mode 3
1282 Type160: When the type is turned off it issued a warning if the voltage was low too.  This warning is now issued as a notice.
1283 Type155 works with Matlab2006a.
1284 Updated settings in workspace for Type155.
1285 Fixed bug in Type9 and Type 16 that caused problems at small time steps and high latitudes.
1286 Type95 - fixed wrong call to SetStorageVars
1287 Type96-modified error message when an error occurs when reading data file
1288 Type31 - added output that allows user to check energy balance
1289 Type31 - fixed bug with storage of previous and current values of temperature and lenghts of fluid segments
1290 Convergence criteria is automatically reduced when using relaxation factors
1292 Added access function getLUFileName.
1293 Type12: Added error check if rated flow rate is set to zero
1294 Type109: sunrise and sunset values are now initialized.
1296 Type194 - modified radiation inputs so they take the same inputs as Type94.
1297 Type194 - fixed error in plug in.
1298 Added new access function getNumberOfWarnings.
1301 Added capability to use filenames such as ***anything.ext where *** gets replaced with the deck filename.
1302 Improved error handling if Logical Unit 0 is used  
1304 Type19: added error message when storage size is exceeded.
1305 Type55: summaries are not reset when the simulation starts at an hour different than 0
1309 Type38: wrong results when there is no internal heater
1310 Type15: error when opening file with status 'NEW' if the files already exist
1311 Fixed error in time report printed by Type109.
1312 Updated libraries for IVF9.1
1313 Type109: read slope and azimuth angles at each time step, using tracking mode 1
1314 Type8: fixed bug that caused controller to fail under some conditions
1315 Type194: plugin can read from 'include194.txt' list of pv modules
1316 Type25 EES: the user may enter the format for the EES lookup tables
1317 The routine CallingPrograms  is now compatible with IVF9.1 and MVS2005
1318 Type67: fixed bug that produced wrong shading calculations
1319 New type: Type21, returns several time values
1320 New type: Type81, performs 1-D interpolation from file
1321 New type: Type83, calculates the first derivative or a variable
1322 New type: Type84, calculates the moving average over N previuos time steps
1323 New type: Type59, lumped capacitance model
1324 New type: Type63: thermophysical properties of substances, using NASA CEA2
1325 Type109: added radiation for user-defined weather data with Ibn and Id
1326 Type109: added initialization of wind speed when no data is read
1327 Type109: fixed division by zero under some conditions of zero radiation
1328 Type194: fixed calculation of incidence angle modifiers
1329 Type25: a new mode that allows to print to a filw, whose name changes depending on the values of variables
1331 NOLIST statement was not working with comments
1332 Type19: fixed problem when several adjacent walls were present
1334 Type94: fixed problem that caused outputs equal to zero when two or more instances were present in a simulation
1338 Added functions getDelt() and getTime0() to the definitions file 'trnsys.h'
Simulation Studio
2167 Fixed filter in Open box/Import deck. Filter set to dck.
2232 Type19: when the outputs from type19 are connected to another component, it now writes the unit corresponding to Type 19, and not the pseudo-type.
2255 Proforma type29, fixed number of parameters
2256 Proforma Type94b, fixed limit for tau-alpha
2257 Proforma Type194, changed inputs so it is similar to type94
2258 Fixed problem when double clicking on a *.tpf file in Windows Explorer.
2259 Updated modelconffile.conf and updatedmodels.txt to reflect changes in location of proformas of printers
2263 Proforma Type 185: units of batery capacity changed to Ah
2264 Proforma Type 57: updated references to Volume 5
2268 Proforma Type19: updated path to file ASHRAE.cof
2272 Fixed crash when using plug-ins
Type 56 and TRNBuild (Multizone building)
3109 Special USE library for using IVF
3110 NTYPE75: was being printed out one step late
3111 Bug in chilled ceiling
3112 humidity calculation has to be turned on for comfort calculation
3113 Allow for exponent equal to zero in convection heat transfer coefficient
3114 Corrected error message concerning pane temperature
3115 TRNBUILD does not allow any boundary temperatures below zero
3116 TRNBUILD: TRNFlow Flow Controller F2 couldn't be turned on (FSCALE=0) 
3117 TRNBUILD: wrong icon for TRNSYS 
3118 TRNFLOW NTYPE 210, 234: division by 0 error at the initialization step
3119 TRNFLOW NTYPE 245, 246, 259: didn't work for ambient air
3120 TRNFLOW NTYPE 244, 259: missing conversion factor 3600 from kg/s to kg/h
3121 TRNFLOW NTYPE 244, 248: Pointerarray AANODE missing 
TRNEdit and TRNExe
4041 When running a Parametric Table, TRNEDIT will execute the directives <BEFORE> and <AFTER> before and after EACH TRNSYS run, correspondingly.  The statements <BEFORE1> and <AFTER1> will only run ONCE before and after the Parametric Table calculations.
4059 TRNEdit: new setting option for saving files after running parametric table. Go to File/Setup and go to the 'TRNSED' tab.
4065 TRNEdit: set different colors for the background and individual groups
4069 TRNEdit: the width of any data file used in a distributable application has been extended to 1000 characters. 
4071 TRNEdit: the extension of the data file used in a distributable application can be anything, not only *.dat.
Fixes in TRNSYS 16.01.0002 (2006-07-07)
Package
0132 Doc: Included a general description of the TRNSYS manuals to the Getting Started manual.
0133 Doc: Modified Volume7, so the input file sintax is found first
0134 Included an example of the file used by Type54 - Weather Data generator 
0135 Doc: added explanation of Release and Debug versions in Getting Started manual
Source Code (Kernel and Standard library of components)
1271 When a user-dll is left in the \UserLib directory, TRNSYS issues a warning instead of a fatal error
1273 Fixed a bug when a simulation used Type121 and Solver 1.
1274 Type2: added initialization of output.
1276 CVF wokspace had a wrong call to TRNExe.exe in the settings for debug version
1277 Type109: fixed error when two or more user-specified components are present in simulation.
Simulation Studio
2251 Type42's proforma contains a better explanation of its inputs.
2253 Deleted proformas-directories that contained duplicated proformas.
2254 Corrected setting in CVF workspace created by the Studio.
Type 56 and TRNBuild (Multizone building)
  none
TRNEdit and TRNExe
  none
Fixes in TRNSYS 16.01.0001 (2006-06-05)
Package
0121 Doc: Type155- Added explanation regarding multiple instances of Type155
0122 Integrated the manual of Type56 and TRNBUILd into the format of the other manuals
0123 Updated the 'Building' example.
0125 Doc: The documentation directory had two copies of A1, A2 and A3
0126 The example 'Restaurant' was updated.
0127 The installation file setup had incorrect registry lines that created a wrong link to the Studio
0128 Doc: In Volume 8, updated the settings for writting User DLLs in CVF
0129 Doc: In Volume 8, updated the settings for the Main DLL in CVF
0130 A new example on how to simulate two instances of Type155 was added to the \Examples directory.
0131 A conflict in the data files used by the example 'ShadingMask' when the main TRNDll.dll is compiled in IVF was solved.
Source Code (Kernel and Standard library of components)
1239 Type62 is now compiled and linked within TRNDll.dll, no need for special call in the CallTypes routine
1246 New functions were added: GTWARN,GEWARN,EQWARN,NEWARN.
1247 Type155 gives the right outputs when multiple units are used in the same project.
1251 The IVF solution file was updated in order to reflect the changes in Release and Debug modes of the user-written dlls.
1254 A new printers was added, which allows to automatically create EES lookup tables.
1256 An error in output 47 of Type16 was fixed.
1258 The error and warning messages from Psycrometrics routine write the IUNIT and ITYPE numbers of the component that called it.
1259 A bug Type35 that produced incorrect values when the radiation is equal to zero was fixed.
1260 Type38's outputs are initialized with values related to the initial inputs.
1261 Types 15 and 16 were improved so they can be used at high latitudes when there is no sunset.
1262 Type4 allows for up to 100 nodes, from a previous maximum of 15.
1263 A bug was fixed in routine 'NewEqn' that caused an error when a variable name starts with END,EQU, INC or CON.
1264 The warnings '4089' in the IVF solution file were resolved.
1265 The settings in the IVF solution were changed so the warnings 4049 and 4217 are not present.
1266 Type101 works now with IVF
1267 Type96 was updated.
1268 Type6 is now called at every time iteration, in order to avoid conflicts at very small time steps.
1270 Two outputs were added to Type30-mode 1: sky and ground reflected diffuse fractions of shaded radiation
Simulation Studio
2239 Type42's proforma contains a better explanation of its inputs.
2241 Delete proformas-directories that contained duplicated proformas.
2243 The extension of the weather file in Type15's proforma was corrected.
2244 The simple-building wizard was updated.
2245 Type55's proforma gives a better explanation of parameter 1.
2246 Type109's proforma allows for slopes greater than 90°.
2247 Type56's parameter (2) can be greater than 1.
2248 Type4's proforma allows for up to 100 nodes.
2249 Type30a's proforma has two new outputs.
Type 56 and TRNBuild (Multizone building)
3056 New INF format - Long names for inputs are not printed to the INF file.
3099 Subroutine balances: output files balances  should be kJ/hr and not STEP.
3100 Subroutine balances: sum outputs of needs to be multiplied with DELT (time step)
3101 For combined mode ABS(PAR(2))>=100), an input/schedule to HRONT / BACK is now possible
3102 Automatic Convective heat transfer coefficient: a problem if defined for back side of adjacent wall only was fixed.
TRNEdit and TRNExe
4062 TRNEXE can be run with option '/h' and online ploter.
Fixes in TRNSYS 16.01.0000 (2006-03-24)
Package
0006 Documentation : pdf index (pdx) does not work in Acrobat 5
0099 Doc Vol 01: various typos
0100 Make a Type68/Type34 example
0107 Doc: Vol05 description of how to use PID in cooling mode
0108 Doc: Vo05: Type16 solar radiation processor explanation
0109 Doc: Vol05: References for Type19
0110 Tutorial Window5
0111 Vol5: typo in type 77, thermal diffusivity
0112 Vol4: Wind direction
0115 Doc: Type194
0117 Doc: Add index of types by number
0118 Example begin. Error with stoptime = 200
0119 Doc: Programmer's guide - INFO(13)
Source Code (Kernel and Standard library of components)
1070 Review all MOD function calls
1124 Type45 is a V15 Type
1125 Type28 printed output in mode 2 should be printed at once for each group of 12 summaries, not line by line
ALSO MISC ISSUES
1129 Type109: Different radiation values for 2-year runs
1130 Type109: Error Messages do not use the standard Messages routine
1147 Functions to access Storage are missing from Trnsys.h
1160 IVF Compatibility: Type109 causes memory access violations
1170 Create a Type68 that uses a single skyline mask for all facades
1173 Type30 (parabollic trough)
1175 get rid of white space at ends of lines in log file. They cause Studio problems
1176 Type18: overstepping reserved OUT( ) array space on initialization
1177 LINKCK writes error messages directly to LUW
1178 LINKCK writes an incorrect error message in addition to a correct, nonstandard message
1181 add a dck level (or compiler level) switch for loading debug vs. release DLLs in \userlib
1182 Type74: bad placement of converting PARs in deg. to rad. 
1183 Type94: subroutines CURRENT4 and CURRENT5 could return negative values
1184 Type94: local vars multiplied by nSer and nPar each iteration
1187 Type94 - divide by zero when tau-alpha for normal incidence was set to 0.0
1188 Type28 - Monthly summaries are incorrect if the simulation starts at an hour different than zero
1190 Type109 - traking mode 3
1194 Type120 - It was not calculating the waste heat for all of the units
1196 Type19
1197 Type70
1198 Type68 - horizontal surfaces
1200 Type 9 - With trnsys15-input file
1201 Update phase-change materials component, written for TRNSYS15
1202 Couple CFD and TRNSYS
1204 Type19 enters an infinite loop if it cannot converge on a zone temperature
1205 Type70 errors if info in input file exceeds data structure capacity
1206 dynamic / static array access speed
1209 Type28 - error when the simulation is stopped
1211 Units:  add electrical units to the list of recognized units
1214 Type28:  writing to the list file
1216 Dynamic storage
1217 Type120: Wrong outputs when more than one unit was used
1218 Check all electrical components to allow the use of electrical units with RCHECK
1219 Type3: the control function is now a boolean type: 0 or 1 
1220 Type39: recalling stored values
1221 Create a new utility component that counts how long a component has been used
1223 Type28 - bad summaries with time step shorter than 1 hour
1224 Type 1- optical mode 4. Error message regarding TAUALPHA function
1226 Type121: wrong size of PAR()
1227 Type90: wrong size of PAR() 
1228 Type74: outlet temperature decreases even with constant inputs
1230 Type109 - error in example 'begin.dck' when stop time=200
1232 Type25-parameter 6
1233 Double error when a type is not pressent
1234 Error if a dll is found in \UserLib
1235 Mismatch between C-boolean and Fortran logical in CallPrograms
1236 Type34 calculation of unshaded total radiation 
1241 Type97should be able to change multiplier values on airflow paths
1242 Type35 maintains does not give the right outputs when radiation is zero.
1244 Type15 - New weather data and radiation processor
1245 Type194 - New component that characterizes the behaviour of photovoltaic panels
Simulation Studio
2050 Suggestion: Shouldn't the deck file automatically take the project filename?
2094 Type89 proforma: missing CWEC and TMY
2098 HYDROGEMS Type100 proforma: difference between a and b
2106 ALL Proformas: Revise and test
2125 Default location for projects
2132 Component order in Control Cards: display type number. Also display the Type number in the proforma itself when you double click (many users know Type numbers)
2166 Global "refresh" of a project
2168 New INF format for Type 56
2203 Both Type110 and Type3b proforma More button corrections
2204 improve COMIS example to include limited COMIS dll
2205 Building Wizard defaults
2209 Type68 proforma error
2213 Export component to Fortran
2218 Type30b.tmf has incorrect number of PARs and INPs if axis slope is not 90 degrees.
2224 Improve equation window
2225 Contam proforma
2226 Modify the default path for generated types dll in userlib
2227 Display the unit and proforma number using F2
2228 Automatic update of proformas in entire project
2234 Type109-proformas:  wind direction should be degrees
2236 Type57 proforma: wrong additional information
2237 New wizards to create coupled projects with COMIS
2238 Wizard does not export the name of the zones if they are changed by user.
Type 56 and TRNBuild (Multizone building)
3067 Output window, hitting enter is not the same as clicking OK
3072 U-value displayed in wall and window manager should include explanation
3078 Active layers - bugs related to energy balance in segments of active layers
3083 Several improvements were done to the .in file:
1. The columns of the INPUT and OUTPUT list have now the separation character "|".
2. New names for INPUT and OUTPUT labels are implenented in order to make them clearer.
3. All label names are unique now. If an output is selected twice or more, the label is changed
   by adding "_#2" and "_#3", respectively.
4. The new Studio updates the old input and output labels of TYPE 56 automatically
   by clicking on "Update building variable list". 
3084 Increased accuracy of Type56: all REAL variables are set to REAL(8)
3085 Increased accuracy of Type56 due to smaller tolerances for inverting matrix.
3086 The combined heat transfer mode using parameter2>=100 did not work, as inputs were ignored.
3087 NTYPE20 (QCOMO) fixed for adjacent walls with active layer.
3088 Error in internal iteration for autosegmentation of active layer and automatic heat transfer coefficient calculation
3089 Problems with negative values of g-glass
3090 Improved calculation of u-glass
3091 Problems with the distributions of internal gains on window panes.
3092 Multiplication and addition factors of schedules and inputs are allowed to be negative
3093 TRNBuild: If a link type of TRNFlow is exchanged by another link type for which an output has been defined, TRNBuild chrashed if you try to save the bui. 
3094 TRNBuild: NTYPE 86 (Requiv) wasn't written to the INF-file
3095 TRNBuild: Properties - text for chilled ceiling was interchanged
3096 TRNBuild: TRNFLOW - straight duct type manager problems displaying correct pictures
3097 TRNBuild: TRNBUILD.INI is saved in same directory as TRNBUILD.EXE
TRNEdit and TRNExe
4051 implement CTRL+V and CTRL+C in Parametric Tables
4054 TRNEdit: tab browsing between windows
4055 TRNEdit: images
4058 Encode .TRD files in distributable
Fixes in TRNSYS 16.00.0038 (2005-06-07)
Package
0030 Examples: Add HYDROGEMS detailed examples
0093 Add CONTAM example
0094 Doc Vol 01: Added section on batch runs and /n, /h switches (section 1.10)
0095 Doc Vol 05: Add description of /h switch to Type65 section
0096 Doc Vol 08: Revise section on compilers (CVF AND IVF)
0097 Doc Vol 08: incorrect list of reserved Type numbers
0098 Doc Vol 07: GE( ), LE( ), and NE( ) are missing
Source Code (Kernel and Standard library of components)
1008 Type109: still a version 15 Type
1061 Unrecognized control card in a TRNSYS 15 deck (Equations starting with EQU, CON, END, INC)
1110 Type68: allow data files with variable step in view angle or generate error
1126 Type109: Speed issue: 1st half of the simulation always faster than second half
1127 Type109: Impossible to run 2 years from December to March
1128 Type109: Interpolation problem when radiation is zero, non-zero, zero again
1131 Type89, EnergyPlus Files: wrong multiplication factors for sky cover (total and opaque)
1132 Psych was printing error message 118 twice to the listing file
1133 Psych: crash when teperature very near 0 deg C
1134 Type1: Crash in some circumstances due to rounding errors on NS, number of collectors in series
1135 Message 431: Add that it can be caused by Excel (or other) locking the file
1136 Type77 is missing from the source code and TRNDll
1137 Type93 problem with multiple units
1139 Many messages in Psych do not use Messages but print directly to the lst file
1140 Type62: crash when multiple units are used
1141 Type18: Typo causes range check error (out array)
1142 Type39: Updaed variable storage algorithm + fixed issue with multiple units
1143 Type120 was not reading PRATED in mode 2 when pars are defined in the deck
1144 Error Message 23 not clear
1145 Type16 unclear error message when user attempts to use smoothing
1146 Some access functions are missing from Trnsys.h, the Include file for C/C++ Types
1148 Type14 issues unclear error message if par(1) > Time0
1149 Type121: heats at full power if Tin > Tset (should stop)
1150 Type40: range check error if too many outputs in v. 15, unclear error msg in v. 16
1151 incorrect list of Types loaded from each external DLL
1152 reset of XIN( ) array in Type160.
1153 Type91, bad crash when flow rates are negative and incorrect "bad parameter value" reported
1154 Type62 is now compiled and linked within TRNDll.dll
1155 Type155 special DLL is now placed in the Exe Folder and loaded with a set of special instructions
1156 IVF Compatibility: Type 62 causes problems in external DLL's and in TRNDLL
1157 IVF Compatibility: Type155 causes problems in external DLL's and in TRNDLL
1158 IVF Compatibility: Type62 causes problems in external DLL's and in TRNDLL
1159 IVF Compatibility: Type28 causes crashes
1163 INCLUDE statement path names could not have spaces in them.
1164 Convergence problems at every iteration with Type1 OPTMODE 4
1167 Error Messages 57 and 86 not clear
1168 Type9 integer overflow
1169 Type34 incorrect results
1171 Type45 missing from DLL
1172 Add Type16 mode for Idn and horiz. Diffuse
Simulation Studio
2179 Components disappear when optimizing order
2184 Building Wizard: some of the created equations use illegal variable names (starting with CON, EQU, END, INC)
2188 Type50 proformas have errors in variable descriptions and units
2190 rounding problem for small time steps if "min" is used for units
2191 Fortran Template uses old forms of Storage access functions
2195 Type68 proforma error
2196 Type97 proforma problems
2197 Type88 proforma errors
2198 Type10 proforma errors
2202 add kg/m.h as Dynamic Viscosity units
Type 56 and TRNBuild (Multizone building)
3046 Wall input: identify front and back
3065 The "Create 4701" function does not work
3068 TRNBuild: Problems with active layers autosegmentation that make the bui file unusable
3069 TRNBuild: more problems with active layers and autosegmentation
3071 cooled ceiling outputs
TRNEdit and TRNExe
4042 Remove all references to TRNSHELL in menus
4043 Remove obsolete menu entries
4044 Print not working for TRNSED windows
4045 TRNExe: silent mode (equivalent to N in second line of cnfgtr.trn in V15)
4046 TRNEdit: Crash with index files
4047 Parametric table: incoherent variable list with "Insert/Delete Vars"
4048 you can't put spaces in the pathname of a *|<PICTURE>
4049 value change update in both views
4050 double click on .trd from Explorer does not open file
Fixes in TRNSYS 16.00.0037 (2005-02-12)
Package
0008 Missing CONTAM manual
0028 Examples: Add a more examples from TRNSYS 15
0031 Doc Vol 01: Add section on examples with some explanations 
0034 Doc Vol 02: not fully integrated
0039 Doc Vol 05: Use existing doc from TRNSYS 15, revise and add new components
0040 Doc Vol 05: Add HYDROGEMS doc
0041 Doc Vol 05: Revise and quality check
0045 Doc Vol 07: Add complete TRNSED language reference + TRNEdit manual, e.g. parametric runs
0046 Doc Vol 07: Add same information as in TRNSYS 15 (basic deck structure, etc.)
0047 Doc Vol 08: Add section how to write a component
0048 Doc Vol 09: Fix some latitude and longitude values for US-TMY2 table
0056 Add example data files
0068 The 2 Wise setup programs for TRNSYS and the weather conflict when uninstalling
0070 Wise Setup: user16.id not copied properly if install dir is not default
0071 Wise Setup (weather): test that destination is valid
0072 Vol 08: add something about errorfound in the info(8)=-1 call
0073 Main index does not use the search index
0074 Vol 08: Add instructions to replace param.inc (or at least change path)
0075 Add example file for Type 54
0076 Add VDI and German TRY weather file examples
0077 Add TESS Type 501 (Simple ground temperature) - Now Type 77
0078 Modify example files for Type 68 to indicate that view angles must cover the -180:180 range with a constant step
0079 Add Type 23 (PID controller)
0080 Add Type 22 (Iterative Feedback Controller)
0081 Vol 08: Complete sections on Global constants and access functions
0082 Check all manuals for #Rev#, #DB#, #, "Error!" (bad references) Figure 0, Eq 0, etc. and empty figures or equations and fix problems in last pdf
0083 Add Feedback control directory to examples with 4 examples using Type 22 and Type 23
0084 Renamed Fuel cell example to Stand-Alone Power System
0085 Add Electrolyzer controller example
0086 Move convergence promoter to obsolete
0087 Add example file for Type 1, optical mode 3
0088 Add example file for Type 1, optical mode 5
0089 Add example files for Type 72 (both efficiency and IAM)
0090 Add detailed TRNSED example with clickable pictures, multiple tabs, etc.
0091 Type 50 proforma par 10 says transmittance-absorptance product, is actually just the transmittance
0092 Add example file for Type 96
Source Code (Kernel and Standard library of components)
1047 Add PID component
1059 Warn users if the order of components is obviously wrong
1065 calling Messages with a Fatal error does not launch the info(8)=-1 call
1083 Error saying that the max nb of warnings is exceeded is printed more than once
1084 Type 109 does not read whether the latitude is N or S in TMY2 mode
1085 Error Message 44 (FORMAT statement not allowed) not there
1086 Type16 outputs zenith=5672 at night, not 99
1087 Check all constants in param.inc
1088 Type16 calculates sunup/sundown times with an undefined EOT value
1089 Type 27 should use variable descriptors and not labels
1090 Missing error messages 56, 506 + typos in a few others
1091 Wrong message types are still used
1092 Type 32: error message if freezing
1093 Numerous error messages are missing in Messages.f90
1094 Error in storage handling in Types 10, 19, 74, 88, 96
1095 Rewind: Missing DLLEXPORT
1096 Type 11: outputs should keep last value if flow = 0
1097 Type 32: Add error if water leaving coil is frozen
1098 Type 68: Use variable format for errors
1099 Detect incorrect output numbers in connections and equations
1100 Type28: Incorrect simulation totals when the summary interval is used in calculations
1101 Type32 bug in test at beginning, never enters the main loop
1103 Proc: error in updating the call list for equations (with EQSOLVER 0)
1104 Type 155:add info(7) and (13) to error messages
1105 Type 155: Problems with multiple units and M-files in different dirs
1106 V15 Types are stepping on V16 spots in the out array
1107 Increase nMaxEquations to 500 for TRNSOL
1108 Proc: Bug with multiple Include statements
1111 Type32: Added fatal error message to avoid division by zero
1112 Type68: Info(6) was not set correctly
1113 Type60: Fixed bug in internal time step calculation (wrong simulation results!)
1114 Type60: Add fatal error when enters an infinite loop
1116 Type4: Problems at initialization, zero outputs, wrong internal energy and incorrect dynamic response
1117 TRNSYS now displays the path of the EXE and TRNDll that were used in the simulation
1118 Type60: Range check error, 1-node horizontal cylinders
1119 Type10: Issue with variable storage (incorrect results, Type does not respond to inputs)
1120 Type10: Added error message if both flows >0
1121 Type68: check that nb of openings not > max allowed
1122 Type68: delete tmp file after simulation
1123 Type45 is missing
Simulation Studio
2105 ALL Proformas: Edit to shorten the HTML-generated documentation
2157 Updating the TPF for TRNSYS 15 Building example: connection lost
2159 Importing decks with IISiBat or Studio comments should work even if component paths have changed
2160 Updating V15 tpf with Type16 in smoothing mode: Connection lost
2161 Type16 proformas: add examples to SHIFT "more" button
2162 Wrong dimensions/units in Type88 proforma
2163 numerous typos in the building wizard
2165 It should be possible to change a par/inp/out name and then do a replace, update a project or import a deck
2169 Passing current TRNSYS install folder to plugins
2170 Replace function for Type 9
2171 Add default file name to Type 54 proformas
2172 Type 27 proformas: default filename + var. descriptors
2173 Type 9 proformas have inconsistent default values for interpolate and average / instantaneous + misc typos
2174 Connection between "Radiation" and "Wing Wall S" in wizard example
2175 Type 68 proforma: wrong cycle on outputs
2176 Import V15 deck with Type16h, deck file without IISiBat comments
2177 Some icons are not consistent (e.g. Type 4, Hydronics)
2178 Add german TRY and VDI modes to Type 109 proformas
2180 Type 17 proforma: wrong cycle
2181 Added recent Types and recently moved Types (22 23 44 77) to ModelconfFile.conf
2182 Moved Type180 from "…\Generic model" to "…\With Data File"
2183 Type 60 proformas have inconsistent default values
2185 Type 72 proformas have numerous errors
2186 Type50b proforma says "transmittance-absorptance" instead of transmittance 
Type 56 and TRNBuild (Multizone building)
3007 TRNBuild requires user16.id in its directory
3045 Win ID pool usability
3053 Wrong error message if step > timebase
3054 Wrong error message if timebase not multiple of timestep
3057 opening Bui files by double-clicking in Windows explorer does not work
3059 Open Source version does not run
3060 It is not possible to define a new weekly schedule as it was in V15
3061 Bug in autosegmentation for multiple active layers
3062 Balance outputs for user defined surface numbers
TRNEdit and TRNExe
4007 TRNExe: .TMP filter in File Open after running parametric table
4009 Open with double-click does not always work?
4013 Error 193 when calling TRNExe
4025 TRNEdit: Windows / output files does not find most output files
4033 TRNSED files must have a ".trd" extension otherwise they are opened as text files
4034 TRNEdit: strange character displayed in the TRNSED Example
4035 Online plotter: mouse draws box after changing y axis limits
4036 TRNSED: the plot menu is gone (it is OK in TRNEdit)
4038 TRNEdit: welcome screen does not look right on some laptops
4039 Radio button and checkbox title not displayed properly
Fixes in TRNSYS 16.00.0036
Package
0067 The version used for the TRNSYS 15 "Building" example had an error: Type16 Start Day was set to the "STADAY" equation without having changed the variable type to String. This is incorrect and theoretically impossible in IISiBat so the TRNSYS 15 example was corrected.
Source Code (Kernel and Standard library of components)
1057 Type 57: error in call to getStorage
1060 EES is not closed after running the 'Calling EES' example
1081 Type65 prints mixed delimiters when running V15 deck
Simulation Studio
2154 Import deck with Type 11b does not work
2158 Conflicts between Type9f in 15 (French weather) and 16 (expert mode).
Type 56 and TRNBuild (Multizone building)
  none
TRNEdit and TRNExe
  none
Fixes in TRNSYS 16.00.0035
Package
0065 Example file for Type 71 (Evacuated tube solar collector) was added
0066 Example and axample file for Type 68 were added (Examples\Shading)
Source Code (Kernel and Standard library of components)
1069 Type 28 was issuing incorrect warnings for timesteps < 1h (the warnings were saying that the summary period is not a multiple of the time step for any summary period)
1077 Type 109 was not working in VDI mode (wrong check on time0)
1079 Type 90 was not updating the power output if wind speed =0
1080 Type28: monthly summaries with start <>0 were not usable. Only the very last summary was printed
Simulation Studio
2149 TRNSED decks: error in START and STOP for projects generated by the Studio (START and STOP are constant no matter what the selection for start month, day, etc. are)
2150 Warnings when importing deck files were referring to wrong unit numbers. They were using the "index" number in the component order tab, in control cards. They new refer to the real unit numbers
2151 "Edit Connections with" was not working in Windows NT
2152 Editing a filename in a macro was crashing the Studio
2153 All examples have been regenerated because some of them were referring to component paths that have changed. All deck files have been re-created in the default location so they can be imported without problems
Type 56 and TRNBuild (Multizone building)
3051 TRNBuild was allowing spaces and other special characters in Types but was not able to read the created bui files again
3052 Type 56 was not updating the wall history correctly for timesteps and/or timebases less than one hour. Results were unpredictable
TRNEdit and TRNExe
  none