| TRNSYS 16 Fix list | |
| This document lists the fixes made to various pieces of the TRNSYS package in response to noted operational problems or inadequacies. They are organized by TRNSYS release and by category (package, Source Code, Studio, Building, TRNEdit/TRNExe) | |
| Fixes in TRNSYS 16.01.0003 (2007-03-28) | |
| Package | |
| 0136 | Doc: Corrected documentation for Type 27, as it mentioned plotting capabilities which are not available now. |
| 0137 | Example: New example shows how to use the detailed single zone building Type9. |
| 0138 | Example: Added a new example that shows the differences between controllers Type8 (thermostat) and Type2 (differential controller). |
| 0139 | Doc: Updated volume 8 Programmer's guide, reference to section 8.4.5 Solving differential equations. |
| 0140 | Doc: Added explanation of energy balance for Type31. |
| 0141 | Doc: Corrected the third level of titles in Volume 5. |
| 0142 | Doc: Fixed bookmarks in documentation for volumes 4 and 5. |
| 0143 | Example: calling matlab was updated in order to allow several instances of Type155 |
| 0144 | Example: calling matlab had an old temporary file. It was deleted |
| 0147 | Example: electrolyzer controller was modified to work with IVF |
| 0148 | Doc: TRNEdit- explanation of EQSOLVER used the wrong range of values |
| 0149 | Example: Added a new example that shows how to create a HVAC system coupled to the building |
| 0150 | Example: Added example that shows how to solve for a component input, knowing the value of the output |
| Source Code (Kernel and Standard library of components) | |
| 1237 | Example 'Electrollyzer Controller' works with IVF |
| 1278 | Fixed bug in Type65. If more than 5 units are present, the first 5 produce an online plotter and the others print to a file. |
| 1281 | Type109 - fixed bug with tracking mode 3 |
| 1282 | Type160: When the type is turned off it issued a warning if the voltage was low too. This warning is now issued as a notice. |
| 1283 | Type155 works with Matlab2006a. |
| 1284 | Updated settings in workspace for Type155. |
| 1285 | Fixed bug in Type9 and Type 16 that caused problems at small time steps and high latitudes. |
| 1286 | Type95 - fixed wrong call to SetStorageVars |
| 1287 | Type96-modified error message when an error occurs when reading data file |
| 1288 | Type31 - added output that allows user to check energy balance |
| 1289 | Type31 - fixed bug with storage of previous and current values of temperature and lenghts of fluid segments |
| 1290 | Convergence criteria is automatically reduced when using relaxation factors |
| 1292 | Added access function getLUFileName. |
| 1293 | Type12: Added error check if rated flow rate is set to zero |
| 1294 | Type109: sunrise and sunset values are now initialized. |
| 1296 | Type194 - modified radiation inputs so they take the same inputs as Type94. |
| 1297 | Type194 - fixed error in plug in. |
| 1298 | Added new access function getNumberOfWarnings. |
| 1301 | Added capability to use filenames such as ***anything.ext where *** gets replaced with the deck filename. |
| 1302 | Improved error handling if Logical Unit 0 is used |
| 1304 | Type19: added error message when storage size is exceeded. |
| 1305 | Type55: summaries are not reset when the simulation starts at an hour different than 0 |
| 1309 | Type38: wrong results when there is no internal heater |
| 1310 | Type15: error when opening file with status 'NEW' if the files already exist |
| 1311 | Fixed error in time report printed by Type109. |
| 1312 | Updated libraries for IVF9.1 |
| 1313 | Type109: read slope and azimuth angles at each time step, using tracking mode 1 |
| 1314 | Type8: fixed bug that caused controller to fail under some conditions |
| 1315 | Type194: plugin can read from 'include194.txt' list of pv modules |
| 1316 | Type25 EES: the user may enter the format for the EES lookup tables |
| 1317 | The routine CallingPrograms is now compatible with IVF9.1 and MVS2005 |
| 1318 | Type67: fixed bug that produced wrong shading calculations |
| 1319 | New type: Type21, returns several time values |
| 1320 | New type: Type81, performs 1-D interpolation from file |
| 1321 | New type: Type83, calculates the first derivative or a variable |
| 1322 | New type: Type84, calculates the moving average over N previuos time steps |
| 1323 | New type: Type59, lumped capacitance model |
| 1324 | New type: Type63: thermophysical properties of substances, using NASA CEA2 |
| 1325 | Type109: added radiation for user-defined weather data with Ibn and Id |
| 1326 | Type109: added initialization of wind speed when no data is read |
| 1327 | Type109: fixed division by zero under some conditions of zero radiation |
| 1328 | Type194: fixed calculation of incidence angle modifiers |
| 1329 | Type25: a new mode that allows to print to a filw, whose name changes depending on the values of variables |
| 1331 | NOLIST statement was not working with comments |
| 1332 | Type19: fixed problem when several adjacent walls were present |
| 1334 | Type94: fixed problem that caused outputs equal to zero when two or more instances were present in a simulation |
| 1338 | Added functions getDelt() and getTime0() to the definitions file 'trnsys.h' |
| Simulation Studio | |
| 2167 | Fixed filter in Open box/Import deck. Filter set to dck. |
| 2232 | Type19: when the outputs from type19 are connected to another component, it now writes the unit corresponding to Type 19, and not the pseudo-type. |
| 2255 | Proforma type29, fixed number of parameters |
| 2256 | Proforma Type94b, fixed limit for tau-alpha |
| 2257 | Proforma Type194, changed inputs so it is similar to type94 |
| 2258 | Fixed problem when double clicking on a *.tpf file in Windows Explorer. |
| 2259 | Updated modelconffile.conf and updatedmodels.txt to reflect changes in location of proformas of printers |
| 2263 | Proforma Type 185: units of batery capacity changed to Ah |
| 2264 | Proforma Type 57: updated references to Volume 5 |
| 2268 | Proforma Type19: updated path to file ASHRAE.cof |
| 2272 | Fixed crash when using plug-ins |
| Type 56 and TRNBuild (Multizone building) | |
| 3109 | Special USE library for using IVF |
| 3110 | NTYPE75: was being printed out one step late |
| 3111 | Bug in chilled ceiling |
| 3112 | humidity calculation has to be turned on for comfort calculation |
| 3113 | Allow for exponent equal to zero in convection heat transfer coefficient |
| 3114 | Corrected error message concerning pane temperature |
| 3115 | TRNBUILD does not allow any boundary temperatures below zero |
| 3116 | TRNBUILD: TRNFlow Flow Controller F2 couldn't be turned on (FSCALE=0) |
| 3117 | TRNBUILD: wrong icon for TRNSYS |
| 3118 | TRNFLOW NTYPE 210, 234: division by 0 error at the initialization step |
| 3119 | TRNFLOW NTYPE 245, 246, 259: didn't work for ambient air |
| 3120 | TRNFLOW NTYPE 244, 259: missing conversion factor 3600 from kg/s to kg/h |
| 3121 | TRNFLOW NTYPE 244, 248: Pointerarray AANODE missing |
| TRNEdit and TRNExe | |
| 4041 | When running a Parametric Table, TRNEDIT will execute the directives <BEFORE> and <AFTER> before and after EACH TRNSYS run, correspondingly. The statements <BEFORE1> and <AFTER1> will only run ONCE before and after the Parametric Table calculations. |
| 4059 | TRNEdit: new setting option for saving files after running parametric table. Go to File/Setup and go to the 'TRNSED' tab. |
| 4065 | TRNEdit: set different colors for the background and individual groups |
| 4069 | TRNEdit: the width of any data file used in a distributable application has been extended to 1000 characters. |
| 4071 | TRNEdit: the extension of the data file used in a distributable application can be anything, not only *.dat. |
| Fixes in TRNSYS 16.01.0002 (2006-07-07) | |
| Package | |
| 0132 | Doc: Included a general description of the TRNSYS manuals to the Getting Started manual. |
| 0133 | Doc: Modified Volume7, so the input file sintax is found first |
| 0134 | Included an example of the file used by Type54 - Weather Data generator |
| 0135 | Doc: added explanation of Release and Debug versions in Getting Started manual |
| Source Code (Kernel and Standard library of components) | |
| 1271 | When a user-dll is left in the \UserLib directory, TRNSYS issues a warning instead of a fatal error |
| 1273 | Fixed a bug when a simulation used Type121 and Solver 1. |
| 1274 | Type2: added initialization of output. |
| 1276 | CVF wokspace had a wrong call to TRNExe.exe in the settings for debug version |
| 1277 | Type109: fixed error when two or more user-specified components are present in simulation. |
| Simulation Studio | |
| 2251 | Type42's proforma contains a better explanation of its inputs. |
| 2253 | Deleted proformas-directories that contained duplicated proformas. |
| 2254 | Corrected setting in CVF workspace created by the Studio. |
| Type 56 and TRNBuild (Multizone building) | |
| none | |
| TRNEdit and TRNExe | |
| none | |
| Fixes in TRNSYS 16.01.0001 (2006-06-05) | |
| Package | |
| 0121 | Doc: Type155- Added explanation regarding multiple instances of Type155 |
| 0122 | Integrated the manual of Type56 and TRNBUILd into the format of the other manuals |
| 0123 | Updated the 'Building' example. |
| 0125 | Doc: The documentation directory had two copies of A1, A2 and A3 |
| 0126 | The example 'Restaurant' was updated. |
| 0127 | The installation file setup had incorrect registry lines that created a wrong link to the Studio |
| 0128 | Doc: In Volume 8, updated the settings for writting User DLLs in CVF |
| 0129 | Doc: In Volume 8, updated the settings for the Main DLL in CVF |
| 0130 | A new example on how to simulate two instances of Type155 was added to the \Examples directory. |
| 0131 | A conflict in the data files used by the example 'ShadingMask' when the main TRNDll.dll is compiled in IVF was solved. |
| Source Code (Kernel and Standard library of components) | |
| 1239 | Type62 is now compiled and linked within TRNDll.dll, no need for special call in the CallTypes routine |
| 1246 | New functions were added: GTWARN,GEWARN,EQWARN,NEWARN. |
| 1247 | Type155 gives the right outputs when multiple units are used in the same project. |
| 1251 | The IVF solution file was updated in order to reflect the changes in Release and Debug modes of the user-written dlls. |
| 1254 | A new printers was added, which allows to automatically create EES lookup tables. |
| 1256 | An error in output 47 of Type16 was fixed. |
| 1258 | The error and warning messages from Psycrometrics routine write the IUNIT and ITYPE numbers of the component that called it. |
| 1259 | A bug Type35 that produced incorrect values when the radiation is equal to zero was fixed. |
| 1260 | Type38's outputs are initialized with values related to the initial inputs. |
| 1261 | Types 15 and 16 were improved so they can be used at high latitudes when there is no sunset. |
| 1262 | Type4 allows for up to 100 nodes, from a previous maximum of 15. |
| 1263 | A bug was fixed in routine 'NewEqn' that caused an error when a variable name starts with END,EQU, INC or CON. |
| 1264 | The warnings '4089' in the IVF solution file were resolved. |
| 1265 | The settings in the IVF solution were changed so the warnings 4049 and 4217 are not present. |
| 1266 | Type101 works now with IVF |
| 1267 | Type96 was updated. |
| 1268 | Type6 is now called at every time iteration, in order to avoid conflicts at very small time steps. |
| 1270 | Two outputs were added to Type30-mode 1: sky and ground reflected diffuse fractions of shaded radiation |
| Simulation Studio | |
| 2239 | Type42's proforma contains a better explanation of its inputs. |
| 2241 | Delete proformas-directories that contained duplicated proformas. |
| 2243 | The extension of the weather file in Type15's proforma was corrected. |
| 2244 | The simple-building wizard was updated. |
| 2245 | Type55's proforma gives a better explanation of parameter 1. |
| 2246 | Type109's proforma allows for slopes greater than 90°. |
| 2247 | Type56's parameter (2) can be greater than 1. |
| 2248 | Type4's proforma allows for up to 100 nodes. |
| 2249 | Type30a's proforma has two new outputs. |
| Type 56 and TRNBuild (Multizone building) | |
| 3056 | New INF format - Long names for inputs are not printed to the INF file. |
| 3099 | Subroutine balances: output files balances should be kJ/hr and not STEP. |
| 3100 | Subroutine balances: sum outputs of needs to be multiplied with DELT (time step) |
| 3101 | For combined mode ABS(PAR(2))>=100), an input/schedule to HRONT / BACK is now possible |
| 3102 | Automatic Convective heat transfer coefficient: a problem if defined for back side of adjacent wall only was fixed. |
| TRNEdit and TRNExe | |
| 4062 | TRNEXE can be run with option '/h' and online ploter. |
| Fixes in TRNSYS 16.01.0000 (2006-03-24) | |
| Package | |
| 0006 | Documentation : pdf index (pdx) does not work in Acrobat 5 |
| 0099 | Doc Vol 01: various typos |
| 0100 | Make a Type68/Type34 example |
| 0107 | Doc: Vol05 description of how to use PID in cooling mode |
| 0108 | Doc: Vo05: Type16 solar radiation processor explanation |
| 0109 | Doc: Vol05: References for Type19 |
| 0110 | Tutorial Window5 |
| 0111 | Vol5: typo in type 77, thermal diffusivity |
| 0112 | Vol4: Wind direction |
| 0115 | Doc: Type194 |
| 0117 | Doc: Add index of types by number |
| 0118 | Example begin. Error with stoptime = 200 |
| 0119 | Doc: Programmer's guide - INFO(13) |
| Source Code (Kernel and Standard library of components) | |
| 1070 | Review all MOD function calls |
| 1124 | Type45 is a V15 Type |
| 1125 | Type28 printed output in mode 2 should be printed at once for
each group of 12 summaries, not line by line ALSO MISC ISSUES |
| 1129 | Type109: Different radiation values for 2-year runs |
| 1130 | Type109: Error Messages do not use the standard Messages routine |
| 1147 | Functions to access Storage are missing from Trnsys.h |
| 1160 | IVF Compatibility: Type109 causes memory access violations |
| 1170 | Create a Type68 that uses a single skyline mask for all facades |
| 1173 | Type30 (parabollic trough) |
| 1175 | get rid of white space at ends of lines in log file. They cause Studio problems |
| 1176 | Type18: overstepping reserved OUT( ) array space on initialization |
| 1177 | LINKCK writes error messages directly to LUW |
| 1178 | LINKCK writes an incorrect error message in addition to a correct, nonstandard message |
| 1181 | add a dck level (or compiler level) switch for loading debug vs. release DLLs in \userlib |
| 1182 | Type74: bad placement of converting PARs in deg. to rad. |
| 1183 | Type94: subroutines CURRENT4 and CURRENT5 could return negative values |
| 1184 | Type94: local vars multiplied by nSer and nPar each iteration |
| 1187 | Type94 - divide by zero when tau-alpha for normal incidence was set to 0.0 |
| 1188 | Type28 - Monthly summaries are incorrect if the simulation starts at an hour different than zero |
| 1190 | Type109 - traking mode 3 |
| 1194 | Type120 - It was not calculating the waste heat for all of the units |
| 1196 | Type19 |
| 1197 | Type70 |
| 1198 | Type68 - horizontal surfaces |
| 1200 | Type 9 - With trnsys15-input file |
| 1201 | Update phase-change materials component, written for TRNSYS15 |
| 1202 | Couple CFD and TRNSYS |
| 1204 | Type19 enters an infinite loop if it cannot converge on a zone temperature |
| 1205 | Type70 errors if info in input file exceeds data structure capacity |
| 1206 | dynamic / static array access speed |
| 1209 | Type28 - error when the simulation is stopped |
| 1211 | Units: add electrical units to the list of recognized units |
| 1214 | Type28: writing to the list file |
| 1216 | Dynamic storage |
| 1217 | Type120: Wrong outputs when more than one unit was used |
| 1218 | Check all electrical components to allow the use of electrical units with RCHECK |
| 1219 | Type3: the control function is now a boolean type: 0 or 1 |
| 1220 | Type39: recalling stored values |
| 1221 | Create a new utility component that counts how long a component has been used |
| 1223 | Type28 - bad summaries with time step shorter than 1 hour |
| 1224 | Type 1- optical mode 4. Error message regarding TAUALPHA function |
| 1226 | Type121: wrong size of PAR() |
| 1227 | Type90: wrong size of PAR() |
| 1228 | Type74: outlet temperature decreases even with constant inputs |
| 1230 | Type109 - error in example 'begin.dck' when stop time=200 |
| 1232 | Type25-parameter 6 |
| 1233 | Double error when a type is not pressent |
| 1234 | Error if a dll is found in \UserLib |
| 1235 | Mismatch between C-boolean and Fortran logical in CallPrograms |
| 1236 | Type34 calculation of unshaded total radiation |
| 1241 | Type97should be able to change multiplier values on airflow paths |
| 1242 | Type35 maintains does not give the right outputs when radiation is zero. |
| 1244 | Type15 - New weather data and radiation processor |
| 1245 | Type194 - New component that characterizes the behaviour of photovoltaic panels |
| Simulation Studio | |
| 2050 | Suggestion: Shouldn't the deck file automatically take the project filename? |
| 2094 | Type89 proforma: missing CWEC and TMY |
| 2098 | HYDROGEMS Type100 proforma: difference between a and b |
| 2106 | ALL Proformas: Revise and test |
| 2125 | Default location for projects |
| 2132 | Component order in Control Cards: display type number. Also display the Type number in the proforma itself when you double click (many users know Type numbers) |
| 2166 | Global "refresh" of a project |
| 2168 | New INF format for Type 56 |
| 2203 | Both Type110 and Type3b proforma More button corrections |
| 2204 | improve COMIS example to include limited COMIS dll |
| 2205 | Building Wizard defaults |
| 2209 | Type68 proforma error |
| 2213 | Export component to Fortran |
| 2218 | Type30b.tmf has incorrect number of PARs and INPs if axis slope is not 90 degrees. |
| 2224 | Improve equation window |
| 2225 | Contam proforma |
| 2226 | Modify the default path for generated types dll in userlib |
| 2227 | Display the unit and proforma number using F2 |
| 2228 | Automatic update of proformas in entire project |
| 2234 | Type109-proformas: wind direction should be degrees |
| 2236 | Type57 proforma: wrong additional information |
| 2237 | New wizards to create coupled projects with COMIS |
| 2238 | Wizard does not export the name of the zones if they are changed by user. |
| Type 56 and TRNBuild (Multizone building) | |
| 3067 | Output window, hitting enter is not the same as clicking OK |
| 3072 | U-value displayed in wall and window manager should include explanation |
| 3078 | Active layers - bugs related to energy balance in segments of active layers |
| 3083 | Several
improvements were done to the .in file: 1. The columns of the INPUT and OUTPUT list have now the separation character "|". 2. New names for INPUT and OUTPUT labels are implenented in order to make them clearer. 3. All label names are unique now. If an output is selected twice or more, the label is changed by adding "_#2" and "_#3", respectively. 4. The new Studio updates the old input and output labels of TYPE 56 automatically by clicking on "Update building variable list". |
| 3084 | Increased accuracy of Type56: all REAL variables are set to REAL(8) |
| 3085 | Increased accuracy of Type56 due to smaller tolerances for inverting matrix. |
| 3086 | The combined heat transfer mode using parameter2>=100 did not work, as inputs were ignored. |
| 3087 | NTYPE20 (QCOMO) fixed for adjacent walls with active layer. |
| 3088 | Error in internal iteration for autosegmentation of active layer and automatic heat transfer coefficient calculation |
| 3089 | Problems with negative values of g-glass |
| 3090 | Improved calculation of u-glass |
| 3091 | Problems with the distributions of internal gains on window panes. |
| 3092 | Multiplication and addition factors of schedules and inputs are allowed to be negative |
| 3093 | TRNBuild: If a link type of TRNFlow is exchanged by another link type for which an output has been defined, TRNBuild chrashed if you try to save the bui. |
| 3094 | TRNBuild: NTYPE 86 (Requiv) wasn't written to the INF-file |
| 3095 | TRNBuild: Properties - text for chilled ceiling was interchanged |
| 3096 | TRNBuild: TRNFLOW - straight duct type manager problems displaying correct pictures |
| 3097 | TRNBuild: TRNBUILD.INI is saved in same directory as TRNBUILD.EXE |
| TRNEdit and TRNExe | |
| 4051 | implement CTRL+V and CTRL+C in Parametric Tables |
| 4054 | TRNEdit: tab browsing between windows |
| 4055 | TRNEdit: images |
| 4058 | Encode .TRD files in distributable |
| Fixes in TRNSYS 16.00.0038 (2005-06-07) | |
| Package | |
| 0030 | Examples: Add HYDROGEMS detailed examples |
| 0093 | Add CONTAM example |
| 0094 | Doc Vol 01: Added section on batch runs and /n, /h switches (section 1.10) |
| 0095 | Doc Vol 05: Add description of /h switch to Type65 section |
| 0096 | Doc Vol 08: Revise section on compilers (CVF AND IVF) |
| 0097 | Doc Vol 08: incorrect list of reserved Type numbers |
| 0098 | Doc Vol 07: GE( ), LE( ), and NE( ) are missing |
| Source Code (Kernel and Standard library of components) | |
| 1008 | Type109: still a version 15 Type |
| 1061 | Unrecognized control card in a TRNSYS 15 deck (Equations starting with EQU, CON, END, INC) |
| 1110 | Type68: allow data files with variable step in view angle or generate error |
| 1126 | Type109: Speed issue: 1st half of the simulation always faster than second half |
| 1127 | Type109: Impossible to run 2 years from December to March |
| 1128 | Type109: Interpolation problem when radiation is zero, non-zero, zero again |
| 1131 | Type89, EnergyPlus Files: wrong multiplication factors for sky cover (total and opaque) |
| 1132 | Psych was printing error message 118 twice to the listing file |
| 1133 | Psych: crash when teperature very near 0 deg C |
| 1134 | Type1: Crash in some circumstances due to rounding errors on NS, number of collectors in series |
| 1135 | Message 431: Add that it can be caused by Excel (or other) locking the file |
| 1136 | Type77 is missing from the source code and TRNDll |
| 1137 | Type93 problem with multiple units |
| 1139 | Many messages in Psych do not use Messages but print directly to the lst file |
| 1140 | Type62: crash when multiple units are used |
| 1141 | Type18: Typo causes range check error (out array) |
| 1142 | Type39: Updaed variable storage algorithm + fixed issue with multiple units |
| 1143 | Type120 was not reading PRATED in mode 2 when pars are defined in the deck |
| 1144 | Error Message 23 not clear |
| 1145 | Type16 unclear error message when user attempts to use smoothing |
| 1146 | Some access functions are missing from Trnsys.h, the Include file for C/C++ Types |
| 1148 | Type14 issues unclear error message if par(1) > Time0 |
| 1149 | Type121: heats at full power if Tin > Tset (should stop) |
| 1150 | Type40: range check error if too many outputs in v. 15, unclear error msg in v. 16 |
| 1151 | incorrect list of Types loaded from each external DLL |
| 1152 | reset of XIN( ) array in Type160. |
| 1153 | Type91, bad crash when flow rates are negative and incorrect "bad parameter value" reported |
| 1154 | Type62 is now compiled and linked within TRNDll.dll |
| 1155 | Type155 special DLL is now placed in the Exe Folder and loaded with a set of special instructions |
| 1156 | IVF Compatibility: Type 62 causes problems in external DLL's and in TRNDLL |
| 1157 | IVF Compatibility: Type155 causes problems in external DLL's and in TRNDLL |
| 1158 | IVF Compatibility: Type62 causes problems in external DLL's and in TRNDLL |
| 1159 | IVF Compatibility: Type28 causes crashes |
| 1163 | INCLUDE statement path names could not have spaces in them. |
| 1164 | Convergence problems at every iteration with Type1 OPTMODE 4 |
| 1167 | Error Messages 57 and 86 not clear |
| 1168 | Type9 integer overflow |
| 1169 | Type34 incorrect results |
| 1171 | Type45 missing from DLL |
| 1172 | Add Type16 mode for Idn and horiz. Diffuse |
| Simulation Studio | |
| 2179 | Components disappear when optimizing order |
| 2184 | Building Wizard: some of the created equations use illegal variable names (starting with CON, EQU, END, INC) |
| 2188 | Type50 proformas have errors in variable descriptions and units |
| 2190 | rounding problem for small time steps if "min" is used for units |
| 2191 | Fortran Template uses old forms of Storage access functions |
| 2195 | Type68 proforma error |
| 2196 | Type97 proforma problems |
| 2197 | Type88 proforma errors |
| 2198 | Type10 proforma errors |
| 2202 | add kg/m.h as Dynamic Viscosity units |
| Type 56 and TRNBuild (Multizone building) | |
| 3046 | Wall input: identify front and back |
| 3065 | The "Create 4701" function does not work |
| 3068 | TRNBuild: Problems with active layers autosegmentation that make the bui file unusable |
| 3069 | TRNBuild: more problems with active layers and autosegmentation |
| 3071 | cooled ceiling outputs |
| TRNEdit and TRNExe | |
| 4042 | Remove all references to TRNSHELL in menus |
| 4043 | Remove obsolete menu entries |
| 4044 | Print not working for TRNSED windows |
| 4045 | TRNExe: silent mode (equivalent to N in second line of cnfgtr.trn in V15) |
| 4046 | TRNEdit: Crash with index files |
| 4047 | Parametric table: incoherent variable list with "Insert/Delete Vars" |
| 4048 | you can't put spaces in the pathname of a *|<PICTURE> |
| 4049 | value change update in both views |
| 4050 | double click on .trd from Explorer does not open file |
| Fixes in TRNSYS 16.00.0037 (2005-02-12) | |
| Package | |
| 0008 | Missing CONTAM manual |
| 0028 | Examples: Add a more examples from TRNSYS 15 |
| 0031 | Doc Vol 01: Add section on examples with some explanations |
| 0034 | Doc Vol 02: not fully integrated |
| 0039 | Doc Vol 05: Use existing doc from TRNSYS 15, revise and add new components |
| 0040 | Doc Vol 05: Add HYDROGEMS doc |
| 0041 | Doc Vol 05: Revise and quality check |
| 0045 | Doc Vol 07: Add complete TRNSED language reference + TRNEdit manual, e.g. parametric runs |
| 0046 | Doc Vol 07: Add same information as in TRNSYS 15 (basic deck structure, etc.) |
| 0047 | Doc Vol 08: Add section how to write a component |
| 0048 | Doc Vol 09: Fix some latitude and longitude values for US-TMY2 table |
| 0056 | Add example data files |
| 0068 | The 2 Wise setup programs for TRNSYS and the weather conflict when uninstalling |
| 0070 | Wise Setup: user16.id not copied properly if install dir is not default |
| 0071 | Wise Setup (weather): test that destination is valid |
| 0072 | Vol 08: add something about errorfound in the info(8)=-1 call |
| 0073 | Main index does not use the search index |
| 0074 | Vol 08: Add instructions to replace param.inc (or at least change path) |
| 0075 | Add example file for Type 54 |
| 0076 | Add VDI and German TRY weather file examples |
| 0077 | Add TESS Type 501 (Simple ground temperature) - Now Type 77 |
| 0078 | Modify example files for Type 68 to indicate that view angles must cover the -180:180 range with a constant step |
| 0079 | Add Type 23 (PID controller) |
| 0080 | Add Type 22 (Iterative Feedback Controller) |
| 0081 | Vol 08: Complete sections on Global constants and access functions |
| 0082 | Check all manuals for #Rev#, #DB#, #, "Error!" (bad references) Figure 0, Eq 0, etc. and empty figures or equations and fix problems in last pdf |
| 0083 | Add Feedback control directory to examples with 4 examples using Type 22 and Type 23 |
| 0084 | Renamed Fuel cell example to Stand-Alone Power System |
| 0085 | Add Electrolyzer controller example |
| 0086 | Move convergence promoter to obsolete |
| 0087 | Add example file for Type 1, optical mode 3 |
| 0088 | Add example file for Type 1, optical mode 5 |
| 0089 | Add example files for Type 72 (both efficiency and IAM) |
| 0090 | Add detailed TRNSED example with clickable pictures, multiple tabs, etc. |
| 0091 | Type 50 proforma par 10 says transmittance-absorptance product, is actually just the transmittance |
| 0092 | Add example file for Type 96 |
| Source Code (Kernel and Standard library of components) | |
| 1047 | Add PID component |
| 1059 | Warn users if the order of components is obviously wrong |
| 1065 | calling Messages with a Fatal error does not launch the info(8)=-1 call |
| 1083 | Error saying that the max nb of warnings is exceeded is printed more than once |
| 1084 | Type 109 does not read whether the latitude is N or S in TMY2 mode |
| 1085 | Error Message 44 (FORMAT statement not allowed) not there |
| 1086 | Type16 outputs zenith=5672 at night, not 99 |
| 1087 | Check all constants in param.inc |
| 1088 | Type16 calculates sunup/sundown times with an undefined EOT value |
| 1089 | Type 27 should use variable descriptors and not labels |
| 1090 | Missing error messages 56, 506 + typos in a few others |
| 1091 | Wrong message types are still used |
| 1092 | Type 32: error message if freezing |
| 1093 | Numerous error messages are missing in Messages.f90 |
| 1094 | Error in storage handling in Types 10, 19, 74, 88, 96 |
| 1095 | Rewind: Missing DLLEXPORT |
| 1096 | Type 11: outputs should keep last value if flow = 0 |
| 1097 | Type 32: Add error if water leaving coil is frozen |
| 1098 | Type 68: Use variable format for errors |
| 1099 | Detect incorrect output numbers in connections and equations |
| 1100 | Type28: Incorrect simulation totals when the summary interval is used in calculations |
| 1101 | Type32 bug in test at beginning, never enters the main loop |
| 1103 | Proc: error in updating the call list for equations (with EQSOLVER 0) |
| 1104 | Type 155:add info(7) and (13) to error messages |
| 1105 | Type 155: Problems with multiple units and M-files in different dirs |
| 1106 | V15 Types are stepping on V16 spots in the out array |
| 1107 | Increase nMaxEquations to 500 for TRNSOL |
| 1108 | Proc: Bug with multiple Include statements |
| 1111 | Type32: Added fatal error message to avoid division by zero |
| 1112 | Type68: Info(6) was not set correctly |
| 1113 | Type60: Fixed bug in internal time step calculation (wrong simulation results!) |
| 1114 | Type60: Add fatal error when enters an infinite loop |
| 1116 | Type4: Problems at initialization, zero outputs, wrong internal energy and incorrect dynamic response |
| 1117 | TRNSYS now displays the path of the EXE and TRNDll that were used in the simulation |
| 1118 | Type60: Range check error, 1-node horizontal cylinders |
| 1119 | Type10: Issue with variable storage (incorrect results, Type does not respond to inputs) |
| 1120 | Type10: Added error message if both flows >0 |
| 1121 | Type68: check that nb of openings not > max allowed |
| 1122 | Type68: delete tmp file after simulation |
| 1123 | Type45 is missing |
| Simulation Studio | |
| 2105 | ALL Proformas: Edit to shorten the HTML-generated documentation |
| 2157 | Updating the TPF for TRNSYS 15 Building example: connection lost |
| 2159 | Importing decks with IISiBat or Studio comments should work even if component paths have changed |
| 2160 | Updating V15 tpf with Type16 in smoothing mode: Connection lost |
| 2161 | Type16 proformas: add examples to SHIFT "more" button |
| 2162 | Wrong dimensions/units in Type88 proforma |
| 2163 | numerous typos in the building wizard |
| 2165 | It should be possible to change a par/inp/out name and then do a replace, update a project or import a deck |
| 2169 | Passing current TRNSYS install folder to plugins |
| 2170 | Replace function for Type 9 |
| 2171 | Add default file name to Type 54 proformas |
| 2172 | Type 27 proformas: default filename + var. descriptors |
| 2173 | Type 9 proformas have inconsistent default values for interpolate and average / instantaneous + misc typos |
| 2174 | Connection between "Radiation" and "Wing Wall S" in wizard example |
| 2175 | Type 68 proforma: wrong cycle on outputs |
| 2176 | Import V15 deck with Type16h, deck file without IISiBat comments |
| 2177 | Some icons are not consistent (e.g. Type 4, Hydronics) |
| 2178 | Add german TRY and VDI modes to Type 109 proformas |
| 2180 | Type 17 proforma: wrong cycle |
| 2181 | Added recent Types and recently moved Types (22 23 44 77) to ModelconfFile.conf |
| 2182 | Moved Type180 from "…\Generic model" to "…\With Data File" |
| 2183 | Type 60 proformas have inconsistent default values |
| 2185 | Type 72 proformas have numerous errors |
| 2186 | Type50b proforma says "transmittance-absorptance" instead of transmittance |
| Type 56 and TRNBuild (Multizone building) | |
| 3007 | TRNBuild requires user16.id in its directory |
| 3045 | Win ID pool usability |
| 3053 | Wrong error message if step > timebase |
| 3054 | Wrong error message if timebase not multiple of timestep |
| 3057 | opening Bui files by double-clicking in Windows explorer does not work |
| 3059 | Open Source version does not run |
| 3060 | It is not possible to define a new weekly schedule as it was in V15 |
| 3061 | Bug in autosegmentation for multiple active layers |
| 3062 | Balance outputs for user defined surface numbers |
| TRNEdit and TRNExe | |
| 4007 | TRNExe: .TMP filter in File Open after running parametric table |
| 4009 | Open with double-click does not always work? |
| 4013 | Error 193 when calling TRNExe |
| 4025 | TRNEdit: Windows / output files does not find most output files |
| 4033 | TRNSED files must have a ".trd" extension otherwise they are opened as text files |
| 4034 | TRNEdit: strange character displayed in the TRNSED Example |
| 4035 | Online plotter: mouse draws box after changing y axis limits |
| 4036 | TRNSED: the plot menu is gone (it is OK in TRNEdit) |
| 4038 | TRNEdit: welcome screen does not look right on some laptops |
| 4039 | Radio button and checkbox title not displayed properly |
| Fixes in TRNSYS 16.00.0036 | |
| Package | |
| 0067 | The version used for the TRNSYS 15 "Building" example had an error: Type16 Start Day was set to the "STADAY" equation without having changed the variable type to String. This is incorrect and theoretically impossible in IISiBat so the TRNSYS 15 example was corrected. |
| Source Code (Kernel and Standard library of components) | |
| 1057 | Type 57: error in call to getStorage |
| 1060 | EES is not closed after running the 'Calling EES' example |
| 1081 | Type65 prints mixed delimiters when running V15 deck |
| Simulation Studio | |
| 2154 | Import deck with Type 11b does not work |
| 2158 | Conflicts between Type9f in 15 (French weather) and 16 (expert mode). |
| Type 56 and TRNBuild (Multizone building) | |
| none | |
| TRNEdit and TRNExe | |
| none | |
| Fixes in TRNSYS 16.00.0035 | |
| Package | |
| 0065 | Example file for Type 71 (Evacuated tube solar collector) was added |
| 0066 | Example and axample file for Type 68 were added (Examples\Shading) |
| Source Code (Kernel and Standard library of components) | |
| 1069 | Type 28 was issuing incorrect warnings for timesteps < 1h (the warnings were saying that the summary period is not a multiple of the time step for any summary period) |
| 1077 | Type 109 was not working in VDI mode (wrong check on time0) |
| 1079 | Type 90 was not updating the power output if wind speed =0 |
| 1080 | Type28: monthly summaries with start <>0 were not usable. Only the very last summary was printed |
| Simulation Studio | |
| 2149 | TRNSED decks: error in START and STOP for projects generated by the Studio (START and STOP are constant no matter what the selection for start month, day, etc. are) |
| 2150 | Warnings when importing deck files were referring to wrong unit numbers. They were using the "index" number in the component order tab, in control cards. They new refer to the real unit numbers |
| 2151 | "Edit Connections with" was not working in Windows NT |
| 2152 | Editing a filename in a macro was crashing the Studio |
| 2153 | All examples have been regenerated because some of them were referring to component paths that have changed. All deck files have been re-created in the default location so they can be imported without problems |
| Type 56 and TRNBuild (Multizone building) | |
| 3051 | TRNBuild was allowing spaces and other special characters in Types but was not able to read the created bui files again |
| 3052 | Type 56 was not updating the wall history correctly for timesteps and/or timebases less than one hour. Results were unpredictable |
| TRNEdit and TRNExe | |